Amps to kilowatts
Kilowatts = amps × volts ÷ 1 000. A 32 A circuit at 230 V delivers 7.36 kW; a 50 A circuit at 240 V delivers 12 kW.
Amps to kilowatts calculator
AC single-phase, power factor 1 · change under Options
Resistive loads (heaters, kettles, incandescent bulbs) have power factor 1. Motors are often 0.8–0.9. For three-phase, enter the line-to-line voltage (for example 208, 400 or 480 V).
How it’s calculated
1 W = 1 V × 1 A · 1 kW = 1 000 W
P (kW) = I × V × PF ÷ 1000
Step by step
- Multiply: 32 A × 120 V = 3,840 W.
- Convert to kilowatts: 3,840 W ÷ 1 000 = 3.84 kW.
Amps to kilowatts table
| Amps | 12 V | 120 V | 230 V | 240 V |
|---|---|---|---|---|
| 1 A | 0.012 kW | 0.12 kW | 0.23 kW | 0.24 kW |
| 5 A | 0.06 kW | 0.6 kW | 1.15 kW | 1.2 kW |
| 10 A | 0.12 kW | 1.2 kW | 2.3 kW | 2.4 kW |
| 15 A | 0.18 kW | 1.8 kW | 3.45 kW | 3.6 kW |
| 20 A | 0.24 kW | 2.4 kW | 4.6 kW | 4.8 kW |
| 30 A | 0.36 kW | 3.6 kW | 6.9 kW | 7.2 kW |
| 32 A | 0.384 kW | 3.84 kW | 7.36 kW | 7.68 kW |
| 40 A | 0.48 kW | 4.8 kW | 9.2 kW | 9.6 kW |
| 50 A | 0.6 kW | 6 kW | 11.5 kW | 12 kW |
| 100 A | 1.2 kW | 12 kW | 23 kW | 24 kW |
Table uses the circuit type and power factor set under Options (AC single-phase, PF 1).
FAQ
For three-phase supplies the formula adds √3 and the power factor; set both under Options.
How do I convert amps to kW?
kW = amps × volts ÷ 1 000 (times the power factor for AC). Three-phase: kW = √3 × amps × volts × PF ÷ 1 000.
How many kW is 100 amps?
100 A is 12 kW at 120 V, 23 kW at 230 V and 24 kW at 240 V (power factor 1).
What voltage should I use?
Use the voltage the device runs on: 120 V for standard North American outlets, 230 V in the UK, Europe and much of the world, 240 V for large North American appliances, and 12 V for car and RV electrics.
What is power factor?
Power factor (PF) is the share of AC current that does useful work. Resistive loads such as heaters and incandescent bulbs have PF 1. Motors and some power supplies are lower, often 0.8 to 0.95, which means they draw more amps for the same watts. Set it under Options.
What about three-phase power?
For a balanced three-phase load, I = P ÷ (√3 × V × PF), where V is the line-to-line voltage. Choose “AC three-phase” under Options.
Can I size a breaker or wire with this?
Unitglide gives the current the load draws. Breakers and wiring must follow your local electrical code, which adds safety margins (for example 80% continuous load rules), so check with a licensed electrician.
Sources
- NIST SP 811 and the SI Brochure (BIPM): 1 W = 1 V × 1 A: P = V × I for DC; P = V × I × PF for single-phase AC; P = √3 × V × I × PF for three-phase AC.